Chapter 9. Remote execution 271
PROFILE data set. When RXSERVE is started, the system issues the messages shown in
Example 9-8.
Example 9-8 RXSERVE startup messages
$$HASP100 RXSERVEB ON STCINRDR
IEF695I START RXSERVEB WITH JOBNAME RXSERVEB IS ASSIGNED TO USER TCPIP GROUP TCPGRP
$HASP373 RXSERVEB STARTED
IEF403I RXSERVEB - STARTED - TIME=10.41.11
EZA4400I Trace options: NOLOG,NOSEND,ALLCLIENTS
EZA4404I Parameters: MSGCLASS=H,TSCLASS=A,TSOPROC=REXECTST,MAXCONN=512,EXIT=REXECEXT
Problem determination for the TSO REXECD server
You can use the MVS MODIFY command to change some of the RXSERVE server operating
parameters during execution. The following parameters ...