3.DC input voltages (a voltage doubler is used for 110VAC)
a.From 110VAC:V
in(low)
=2(1.414)(90VAC) =254VDC
V
in(hi)
=2(1.414)(130VAC) =368VDC
b.From 220VAC:V
in(low)
=1.414(185VAC) =262VDC
V
in(hi)
=1.414(270VAC) =382VDC
4.Average input currents (dc)
a.Highest average:I
in(max)
=350W/254VDC =1.38A
b.Lowest average:I
in(min)
=350W/382VDC =0.92A
5.Estimated maximum peak currentI
pk
=2.8(280W)/254VDC =3.1A
Design decisions
This is going to be a current-mode controlled half-bridge topology. ...