API –610 (7th Ed.) Hydraulic Institute Standard, ANSI
and Industry Practice
Capacity at
rated head
– +10/−0% +5/−5%
Efficiency − 0.5% 0% Formula
Rated Power +4% – –
NPSH-r−3%
head drop
+0 m
Retest When reduction in impeller diameter
demands more than 5% of original
diameter
When reduction in impeller diameter
demands more than 5% of original
diameter
Mechanical
seal
Leakage
test
Mutual agreement Not specified
7.3 Performance test procedure
The performance test of horizontal or vertical pumps needs different configurations of the
pump testing facility
Typic ...