Chapter 16. High availability and failover 523
secondary site and the target is the primary site. The following steps are
necessary for the reversing process:
1. First of all, Log Shipping must be reversed to go from the active secondary
site to the primary site. It is important to note that the actual reverse failover
process can be delayed for maintenance or testing purposes. However, Log
Shipping must be run at all times. Invoke Log Shipping using the command
sh fo_logship -R -T. The -R parameter indicates that this is a
reverse-direction Log Shipping.
2. Verify that Log Shipping has been successfully deployed by checking the Log
Shipping log in fo_logship.cmd.<pid>.log in the TivoliManager\Logs\ directory.
The <pid> is a numeric variable ...