Trouble Ticket Solutions

These solutions are not always the only way to perform these tasks. Compare your results.

Trouble Ticket 1 Solution

First connect the physical cable between r5 and the frame switch. Then configure the frame switch to handle the new PVC, and then r1 and r5 as in Example 8-33.

Example 8-33. Configuring the Frame Switch, r1, and r5
							!!!frame switch configuration for new PVC
frame-switch#configure terminal
frame-switch(config)#interface s0/3
frame-switch(config-if)#bandwidth 64
frame-switch(config-if)#clock rate 64000
frame-switch(config-if)#encap frame
frame-switch(config-if)#frame-relay intf-type dce
frame-switch(config-if)#frame route 101 interface s0/0 105
frame-switch(config-if)#no shut
frame-switch(config-if)#end frame-switch# ...

Get CCNP Practical Studies: Troubleshooting now with the O’Reilly learning platform.