Table 7-11

Assessment Results for Maximum Ice Load with a Thickness of 30 cm

NodeMemberMaximumStressMPa[a]/BSmm[a]/CVDAmmWallThicknessmm2cmmammamAssesment
371273–37172.80631.90329.186.5420X
371373–37180.3330.98128.7886.53035.86
371473–37184.50684.45940.7866.52022.92
515335–51591.61491.25141.5336.31011.2
515513–515190.88621.74624.0446.3430x
515517–51577.9131.27228.9136.3120X
519339–51992.13891.79641.5896.550519.7
531433–531148.70124.53725.6576.53035.86
617718–617226.3519.84822.8374.61923.7
633625–63398.42128.96827.8873.52024.97
633644–633139.20325.26726.0513.5110x
653645–653114.51227.38527.1333.5150x
653664–653335.51315.64519.783.545x
675774–675134.933178.96346.7476.251011.21
677666–67739.14457.25936.5893.52024.97
732631–732–497.221999.009996.25 ...