CHAPTER 16

Line Inputs and Outputs

16.1  External Signal Levels

There are several standards for line signal levels. The −10 dBv standard is used for a lot of semi-professional recording equipment as it gives more headroom with unbalanced connections—the professional levels of +4 dBu and +6 dBu assume balanced outputs which inherently give twice the output level for the same supply rails as it is measured between two pins with signals of opposite phase on them. See Table 16.1.

Signal levels in dBu are expressed with reference to 0 dBu = 775 mV rms; the origin of this odd value is that it gives a power ofz 1mW in a purely historical 600 Ω load. Signals in dBv (or dBV) are expressed with reference to 0 dB = 1.000 V rms.

These standards are well ...

Get The Design of Active Crossovers now with the O’Reilly learning platform.