Table 10.A.1: Extended Process Categorization
| CategoryCalculationsKWh = (KW)*(Annual Hours)KWh = (HP)*(0.746 KW/HP)*(Annual Hours)KWh = ((V)*(Ah))/1000)*(Charges/Day)*(Days of Production) | Energy sources | Electric | Battery | Pneumatic | Hydraulic | Natural Gas | |||
| KWh = ((CFM)/4)* (0.746 KW/HP)* (Annual Hours) | KWh = (KW)* (Annual Hours) KWh = (HP)*(0.746 KW/HP)*(Annual Hours) | KWh = (MMBTU/Day)*(293 KWh/MMBTU)*(Days of Production) | |||||||
| Energy Framework | Direct | Value Added | Joining | Assembly | X | X | X | X | |
| Weld | X | ||||||||
| Glue | X | X | X | ||||||
| Rivet | X | X | X | X | |||||
| Coating | Paint | X | |||||||
| Separating | Grind | X | X | X | |||||
| Disassembly | X | X | X | X | |||||
| Non-Value Added | Material Delivery | Fork Truck | X | X | |||||
| Tow Tractor | X | X | |||||||
| Positioning | Hoist | X | X | ||||||
| Fixtures | X | X | X | ||||||
| Feeding | Chain Drive | X | |||||||
| Conveyor | X | ||||||||
| Indirect Energy | Lighting | X | |||||||
| Heating | X | X | |||||||
| Cooling | X | ||||||||
| Ventilation | X | ||||||||
| Process | X | X | |||||||
| Additional Considerations | -KW rating | -Battery Capacity-Charger Rating-Battery Life | -Air Leaks-Friction Losses-Air Compressor-Air Pressure | -KW Rating-Friction Losses-Hydraulic Fluid Leaks | -Gas Leaks-Heat Losses | ||||