August 2019
Intermediate to advanced
570 pages
15h 1m
English
The information that's displayed in interactive mode is refreshed at regular 5-second intervals. This can be modified by hitting the s key while in interactive mode, specifying the interval in seconds, and hitting Enter to make the change take effect, as shown in the following screenshot:

The esxtop output can be further customized in terms of the metrics and counters that are displayed on the screen. Once you have launched esxtop, while in any metric view, hit the F key to bring up the field customization view.
Here, you can choose to include or not include a field/column by hitting the alphabet key ...