70 Handbook of Magnetic Measurements
We can also see that DW spacing depends on the
length of domain. It is known that losses in silicon steel
depend strongly on the domain width (Figure 2.118b)
due to eddy current loss (Nozawa et al. 1996, O’Handley
2000). Therefore, many technologies were developed,
which improve quality of electrical steel quality by
domain renement (Nozawa et al. 1996). For example,
additional tensile stress is often introduced in electri-
cal steel (by special coating layer) to divide domain into
narrower ones (Figure 2.119a). In another technology
used in the case of grain-oriented steel, the surface ...