229Engineering Solutions for Dust Release Containment and Air Dedusting
© 2010 Taylor & Francis Group, LLC
height from the upper conveyor to the bottom of the inclined chute section is large
enough (H > 1 m), particles ricochet and spread through the entire cross-section. If
the total length of the inclined section is greater than one-half of the fall height, such
a ow shall be aerodynamically considered a pseudo-uniform ow of particulate
matter in a chute.
5.1.3.2 Conveyor (Feeder)–Crusher–Conveyor
A handling facility with a separate crusher unit (without preliminary screening) dif-
fers from an ordinary conveyor-to-conveyor design mainly by ...