274 Industrial Air Quality and Ventilation
© 2010 Taylor & Francis Group, LLC
plant. Dust-laden air was passed through the magnetic grid element at a ow rate
= 7 m/s, with a concentration of 500 mg/m
3
(of pellet dust
= 4,000 kg/m
3
) and
the following particulate composition:
Particle size (m)
< 1.4 1.4–4.2 4.2–9.8 9.8–15 15–30 30–45 45–105
Content by mass (%)
1.2 0.7 4.4 7.4 26.3 26 34
Average Stokes number (at median diameter d
50
= 40 m)
=
=
−
4000 40 10 7
12 18 15 10 013
10
6
.
.
For a single-row grid, according to Table 5.14, the purely inertial settling factor
(at δ/H = 0.5) would be η
1
= 0.4; for two rows installed in a series, ...