anywhere from a few to several hundred milliseconds. It is almost entirely determined
by the size of the main reservoir capacitor, since this provides the only source of power
when the input is removed. A linear regulator can be considered as a constant-current
sink discharging this capacitor and therefore it is easy to calculate the hold-up time for
a given load and input voltage. A switch-mode regulator draws more current as its input
voltage drops, so accurately determining hold-up time for this type requires the solution
of a current-time integral. The higher the operating voltage, the easier it is to obtain ...
Become an O’Reilly member and get unlimited access to this title plus top books and audiobooks from O’Reilly and nearly 200 top publishers, thousands of courses curated by job role, 150+ live events each month, and much more.
O’Reilly covers everything we've got, with content to help us build a world-class technology community, upgrade the capabilities and competencies of our teams, and improve overall team performance as well as their engagement.
Julian F.
Head of Cybersecurity
I wanted to learn C and C++, but it didn't click for me until I picked up an O'Reilly book. When I went on the O’Reilly platform, I was astonished to find all the books there, plus live events and sandboxes so you could play around with the technology.
Addison B.
Field Engineer
I’ve been on the O’Reilly platform for more than eight years. I use a couple of learning platforms, but I'm on O'Reilly more than anybody else. When you're there, you start learning. I'm never disappointed.
Amir M.
Data Platform Tech Lead
I'm always learning. So when I got on to O'Reilly, I was like a kid in a candy store. There are playlists. There are answers. There's on-demand training. It's worth its weight in gold, in terms of what it allows me to do.