Chapter 10
We can ask—where does the leakage inductance really reside? Most of it is inside the
primary winding of the transformer
, though some of it lies in the PCB trace sections and
transformer terminations, especially with those associated with the secondary winding, as
we will see below.
10.1.6 Zener Clamp Dissipation
If we burn the energy in the leakage, it is important to know how this affects the effi ciency.
It is sometimes intuitively felt the energy dissipated every cycle is just 1/2 L
LKP
I
PK
2
,
where I
PK
is the peak switch current, and L
LKP
is the primary-side leakage. That certainly
is the ...