Push-pull circuits are not well suited to voltage mode IC controllers because any fl ux
imbalance in one leg of the transformer primary will eventually saturate the transformer
core. A current mode controller will control the imbalance and limit the current through
both legs. One switch and one winding of the transformer may still carry more load than
the other, but the total fl ux in the core is controlled by limiting the maximum current in
each winding.
Figure 6.18 shows a representative push-pull converter. Notice that the secondary side uses
a center-tapped full wave rectifi ...
Become an O’Reilly member and get unlimited access to this title plus top books and audiobooks from O’Reilly and nearly 200 top publishers, thousands of courses curated by job role, 150+ live events each month, and much more.
O’Reilly covers everything we've got, with content to help us build a world-class technology community, upgrade the capabilities and competencies of our teams, and improve overall team performance as well as their engagement.
Julian F.
Head of Cybersecurity
I wanted to learn C and C++, but it didn't click for me until I picked up an O'Reilly book. When I went on the O’Reilly platform, I was astonished to find all the books there, plus live events and sandboxes so you could play around with the technology.
Addison B.
Field Engineer
I’ve been on the O’Reilly platform for more than eight years. I use a couple of learning platforms, but I'm on O'Reilly more than anybody else. When you're there, you start learning. I'm never disappointed.
Amir M.
Data Platform Tech Lead
I'm always learning. So when I got on to O'Reilly, I was like a kid in a candy store. There are playlists. There are answers. There's on-demand training. It's worth its weight in gold, in terms of what it allows me to do.