Enhancing the voltage reference design
An Introduction to Voltage References
349
als involved, such as the housing of the trimmer, will survive the 150˚C temperature.)
The burn-in process tends to stabilize the various drifts and improve the long-term sta-
bility. Once this is done you should measure again, and if necessary readjust the refer-
ence at 25˚C and at the two operating temperature extremes. After that, no further
adjustment should be necessary.
For devices that have
no
built-in trim capability, one must use an op amp circuit to
make any output adjustment or use some form of compensation circuit. One can eas-
ily scale and amplify the ref ...