Appendix B
Understanding Op Amp Parameters
B.1. Introduction
This appendix explains op amp data sheet parameters. There are usually three main sections of electrical tables in op amp data sheets.
B.1.1. Absolute Maximum Ratings
Absolute maximum ratings are those limits beyond which the life of individual devices may be impaired and are never to be exceeded in service or testing. Limits, by definition, are maximum ratings, so if double-ended limits are specified, the term will be defined as a range (e.g., operating temperature range).
B.1.2. Recommended Operating Conditions
Recommended operating conditions have a similarity to maximum ratings in that operation outside the stated limits could cause unsatisfactory performance. Recommended operating conditions, ...