RD Basic Operational Characteristics
For convenience sake, the basic characteristics of the RD service type, which were provided in “Reliable Datagram (RD) Service Type” on page 67, are replicated here:
Connection needed. Before any messages may be transferred, a connection must be established between the EECs in the two CAs, and the EECs are each programmed with the identity of the remote EEC as well as the address of the port behind which the remote EEC resides. This is necessary so the two EECs can transmit packets to each other.
Message size. Each message can be anywhere from zero to 2GB in size. Large messages are segmented into multi-packet transfers.
Ack/Nak protocol. An Ack/Nak protocol permits the requester (i.e., the Send Logic of the ...