isis hello-multiplier — interface
isis hello-multiplier value [{level-1 |level-2}]
no isis hello-multiplierThe holdtime value multiplier
3
For IS-IS, the holdtime is
calculated by taking the hello interval and multiplying it by the
hello multiplier. This command sets the hello multiplier to
value. By changing the hello multiplier,
you effectively change the holdtime. The optional
level-1 and level-2 keywords
allow you to apply this command to an individual level; otherwise the
interval is applied to both levels.
The following commands configure IS-IS routing for the interface
ethernet 1. The hello interval is set to 5 seconds
(for level 1) and the multiplier is set to 5, yielding a holdtime of
25 seconds.
interface ethernet 1 ip router isis isis hello-interval 5 level-1 isis hello-multiplier 5 level-1