410 Embedded systems design
With the PC-based testing completed, the system could be
installed and tested in the car itself. This was initially done in the
garage while stationary and then with a passenger using the
system while the car was driven. Once all this was completed, the
system and car were taken to a race track and the system used in
anger during the day’s testing. This final testing revealed several
problems with the system.
Problems
Saving to hard disk
The logged data is saved to disk so that it can be read back
at a later date. The data is sent to disk every time a sample set is
received. This is typically completed before the next sample ...