153
fl oorplanner and statistical methods, and then counting the number of times an
interconnect changes direction. Although the via power P
via
is dependent on
the layer in which it resides, this is not taken into account in the model, which
uses approximate values of P
via
by taking its average for different confi gurations
(or optionally using a weighting factor to each via confi guration representing its
proportional contribution to all the vias in the layout). The power consumed by
vias used in repeaters is not estimated by Eq. (5. 13), but is accounted for in the
repeater power consumption term, described below.
5.1.3.3 Power Due to Repeaters ...